GOWB806 - Outdoor Double Jacket Central Loose Tube Steel Wire Armour 06 Fibers G652D/G657A1-OS2


Outdoor Steel Wire Armour Double Jacket Rodent Protection Central Loose Tube Optical Cable 06 x 9/125-G652D/G657A1-OS2 A-DQ(ZN)2Y(SR)2Y

Product Overview

Suitable Applications: For outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial.

Fiber Specifications

Fiber Type: OS2
Fiber Grade Acc to ITU-T: G652D & G657A1
Fiber Core Diameter: 9 µm
Fiber Count: 6
Fiber Color Coding: TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White

Cable Construction

Number of Active Subunits: 1
Subunit Waterblocking: Gel Filled
Subunit Diameter: 4.2 mm
Subunit Color: TIA coding (Gxxxxxx.T): Natural
Cable Core Water Blocking: Waterblocking Glass Yarns

Inner Jacket Specifications

Material: PE - Polyethylene
Nominal Diameter@InnerJacket1 (cnv): 8.7 mm (0.34 in)

Armor Specifications

Armor Type and Material: SWA - Steel Wire Armor

Outer Jacket Specifications

Jacket Material: PE - Polyethylene

Mechanical Characteristics

Mechanical Tests
DescriptionTested StandardAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E6IEC 60794-3-10
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E11IEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E1IEC 60794-3-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E1IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E3IEC 60794-3-10
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E3IEC 60794-3-10
Minimum Bend Radius During Installation: 270 mm
Minimum Bend Radius During Operation: 135 mm
Max. Tensile Strength During Installation: 3750 N (843 lbf)
Max. Tensile Strength During Operation: 1250 N (281 lbf)
Bulk Cable Weight: 268 kg/km (180 lbs/1000ft)

Temperature Range

Installation Temperature Range: -5 °C to +50 °C
Operating Temperature Range: -30 °C to +70 °C
Storage Temperature Range: -30 °C to +70 °C

Standards and Compliance

Environmental Suitability: Outdoor
ISO/IEC Compliance: IEC 60794ISO/IEC 11801-1

History

Update and Revision: Revision Number: 0.108 Revision Date: 09-07-2025

Part Numbers

Variants
Item #ColorPutup TypeLength
GOWB806.002100BlackReel2,100 m
Fiber_Cable_Installation_Guide_202009.pdf