Product Hierarchy
Product Hierarchy

AEHC Accessories - Heat Containment System Accessories


Adaptive Cabinet Heat Containment System Accessories

Application

Product Overview: Belden's active Adaptive Enclosure Heat Containment (AEHC) System is a highly efficient and cost-effective method for cooling cabinets while preventing the mixing of hot and cold air in the data center. When networked, AEHC chimneys allow aggregation of exhaust air volume of entire cabinet pods, enabling real-time control of CRAC units and creating a logical link between the cooling plant and the computing load. this unique attribute allows reduction of cooling-operating costs, particularly in virtualized, clustered computing environments characterized by highly dynamic computing loads. AEHC uses high-capacity fans controlled by a pressure sensor to ensure dynamic balancing of intake and exhaust air volumes Maintains neutral pressure in the cabinet plenum for highly efficient server fan operation Can be networked in a pod/row for redundancy in virtualized, clustered computing environments Multiple cabinets can share AEHC chimneys based on hosted computing density (three cabinets per chimney is typical) AEHC is highly scalable with chimneys added as needed with increased computing loads A pair of hot swappable brushless fans with a combined capacity of 10 kW or 30 kW connect to the AEHC controller, enabling quick and easy capacity upgrades ( different capacity fans cannot be used in the same cabinet) Fan motors are engineered to ensure longevity, high air displacement and low power consumption for mission-critical facilities Ideal for existing data centers, and non-Belden cabinets can be retrofitted with chimney by using a customized adapter plate The AEHC system is powered (autosensing 120V or 208V) via the cabinet PDUs and accepts two distinct power feeds for redundancy A combination of temperature-humidity sensors with AEHC controller can collect and store environmental data. When networked, real-time data can be accessed via the intuitive user interface or Belden Corman-CS Infrastructure Management Software using SNMP (MIB File) Environmental, mechanical and electrical thresholds and alarms are easy to configure and can be sent directly to e-mail addresses (through an escalation process)
Environmental Space: Indoor

Related Part Numbers

Variants
Part #DescriptionColor
HCH001AEHC Controller (1) with Power CordsBlack
HCP001AEHC Pressure Sensor (1)No Color
HCP002AEHC Dual Function Temperature/Humidity Sensor (1)No Color
HCC001-BAEHC ChassisBlack
HCC001-WAEHC ChassisWhite
HCCBP-BAEHC Chassis Blanking PanelBlack
HCCBP-WAEHC Chassis Blanking PanelWhite
HCDBP-BChimney Blank Panel for Active or Passive Containment Black
HCDBP-WChimney Blank Panel for Active or Passive ContainmentWhite
Update and Revision: Revision Number: 0.34 Revision Date: 05-31-2024
No accessories are available for this product