Product Hierarchy
Product Hierarchy

2505PTZ - PTZ, RG-59 #20, #18-1pr, #16-2c, Shielded, CM, Siamese


PTZ (CCTV + Control + Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-18 AWG stranded bare copper pair with PVC insulation and Beldfoil® shield, 2-16 AWG stranded bare copper conductors with PVC insulation, Siamese with PVC jacket, Aluminum interlocking armor

Physical Characteristics (Overall)

Conductor
ElementAWGStrandingMaterialNominal DiameterNo. of ConductorsNo. of PairsNo. of Coax
Coax20SolidBC - Bare Copper0.032 in11
Shielded Pair187x26BC - Bare Copper1
Power conductors1619x29BC - Bare Copper2
Conductor Count: 5
Insulation
MaterialNominal DiameterNominal Wall Thickness
Gas-injected FHDPE - Foam High Density Polyethylene0.145 in
PP - Polypropylene0.008 in
PP - Polypropylene0.008 in
Color Chart
NumberColor
Coax coreNatural
Shielded pairRed and Black
Power conductorsRed and Black
Coax jacketBlack
Shielded ppair jacketBlue
Power jacketWhite
Color Chart 4
NumberColor
1Black
1Gray
1White
Inner Shield Material
TypeMaterialMaterial Trade NameCoverage [%]Drainwire AWGDrainwire Construction n x D
BraidBC - Bare Copper93.0 %247x32
TapeAluminum Foil-Polyester TapeBeldfoil® with shorting fold100.0 %
Unshielded
Outer Shield Material
Drainwire Construction n x D
7x28 mm
Outer Shield Table Note: Polyester
Outer Jacket Material
MaterialNominal Diameter
PVC - Polyvinyl Chloride0.165 in
PVC - Polyvinyl Chloride0.496 in
Unjacketed

Construction and Dimensions

Armor
Type of ArmorMaterialDiameter over Armoring
InterlockedAluminum0.633 in

Electrical Characteristics

Conductor DCR
ElementNominal Conductor DCRNominal Conductor DCR Conductor ResistanceNominal Inner Shield DCR
Coax10 Ohm/1000ft10 Ohm/1000ft3.5 Ohm/1000ft
Shielded pair6.5 Ohm/1000ft4.2 Ohm/1000ft
Power Conductors4.2 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to ConductorNom. Capacitance Conductor to Other Conductor to ShieldNom. Capacitance Conductor to Shield
16.3 pF/ft
53 pF/ft95.5 pF/ft
Inductance
Nominal Inductance
0.097 µH/ft
0.145 µH/ft
Impedance
Nominal Characteristic Impedance
75 Ohm
High Frequency (Nominal/Typical)
Frequency [MHz]Nom. Insertion Loss
1 MHz0.3 dB/100ft
5 MHz0.65 dB/100ft
10 MHz0.9 dB/100ft
50 MHz1.9 dB/100ft
100 MHz2.6 dB/100ft
200 MHz3.6 dB/100ft
400 MHz5 dB/100ft
700 MHz7 dB/100ft
900 MHz8 dB/100ft
1000 MHz8.5 dB/100ft
Delay
Max. Delay SkewNominal DelayNominal Velocity of Propagation (VP) [%]
83 ns/100m1.22 ns/ft83 %
Current
Max. Recommended Current [A]
5 Amps per conductor @ 25°C
Per conductor @ 25°C: 5 A
Voltage
UL Voltage Rating
300 V RMS

Temperature Range

Operating Temp Range: -10°C To +75°C
Separation Temp Range: 0°C To +75°C

Mechanical Characteristics

Bulk Cable Weight: 142 lbs/1000ft
Max Recommended Pulling Tension: 210 lbs
Min Bend Radius/Minor Axis: 9.5 in

Standards

NEC Articles: 800
NEC/(UL) Specification: CMG
CEC/C(UL) Specification: CMG
RG Type: 59/U Type
Other Standards: Coax: RG 59/U

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU: Yes
EU Directive Compliance: Yes
EU CE Mark: Yes
EU RoHS Compliance Date (yyyy-mm-dd): 2007-06-08
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes

Suitability

Suitability - Indoor: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL1685 Vertical Tray Flame Test
UL voltage rating: 300 V RMS

Plenum/Non-Plenum

Plenum (Y/N): No

Part Number

Variants
Item #ColorUPCFootnote
2505PTZ 0001000Black612825132042C
Footnote: C - CRATE REEL PUT-UP.

Product Notes

Notes: RG59 CCTV + 2C 18 AWG Shld + 2 C 16 AWG CMR. Individually jacketed and color coded components, cabled with an overall aluminum interlocked armor.

History

Update and Revision: Revision Number: 0.258 Revision Date: 08-22-2019
Date: 2007-06-08
No accessories are available for this product