Product Hierarchy
Product Hierarchy

1861A - Speaker Cable, 2 Conductor 14 AWG BC, Unshielded, CMP




Speaker Cable, 2 Conductor 14 AWG stranded high conductivity bare copper conductors with Flamarrest® insulation, cabled in an open twisted construction, Plenum-CL2P.

Product Overview

Suitable Applications: Speaker Cable

Physical Characteristics (Overall)

Conductor
AWGStrandingMaterialNo. of Conductors
1419x27BC - Bare Copper (High Conductivity)2
Conductor Count: 2
Insulation
MaterialMaterial Trade NameNominal Wall Thickness
PVC - Polyvinyl ChlorideFlamarrest®0.022 in
Outer Shield
Material
No Shield
Outer Jacket
Nominal Diameter
0.236 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR
2.6 Ohm/1000ft
Inductance
Nominal Inductance
0.17 µH/ft
Current
Max. Recommended Current [A]
8.1 Amps per Conductor at 25ºC
Voltage
UL Voltage Rating
150 V RMS

Temperature Range

Non-UL Temp Rating: 75°C
Operating Temperature Range: -20°C To +75°C

Mechanical Characteristics

Bulk Cable Weight: 33 lbs/1000ft
Max. Pull Tension: 95 lbs
Min. Bend Radius/Minor Axis: 2.5 in

Standards

NEC/(UL) Compliance: CL2P
CPR Euroclass: Eca

Applicable Environmental and Other Programs

Environmental Space: Indoor - Plenum
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: No
MII Order #39 (China RoHS): Yes

Suitability

Suitability - Indoor: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: NFPA 262
IEC Flammability: IEC 60332-1-2
UL voltage rating: 150 V RMS

Plenum/Non-Plenum

Plenum (Y/N): Yes

Related Part Numbers

Variants
Item #ColorPut-Up TypeLengthUPC
1861A D261000Black & Natural PairReel1,000 ft612825125150
Footnote: C - CRATE REEL PUT-UP.

History

Update and Revision: Revision Number: 0.393 Revision Date: 02-15-2024
Date: 2005-04-01
No accessories are available for this product